4. Electrical Wiring
The Pro Logic Control Center requires both high and low voltage connections. Low voltage connections will be made
to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as
providing direct input power to the Control Center. Always:
-Ensure that Power is disconnected prior to doing any wiring
-Follow all local and NEC (CEC if applicable) codes
-Use copper conductors only
Main Service (Power to the Circuit Breaker Subpanel)
The Pro Logic circuit breaker subpanel is rated for 100A service. Run properly rated conductors (L1, L2, N, and
ground) from the primary house electrical panel to the main power connections on the Pro Logic circuit breaker base.
The connection at the main house panel should be to a 240VAC circuit breaker rated at 100A maximum.
Grounding and Bonding
Connect a ground wire from the primary electrical panel to the Pro Logic ground bus bar. Also ground each piece of
high voltage (120 or 240VAC) equipment that is connected to the Pro Logic control relays or circuit breakers. The
Pro Logic should also be connected to the pool bonding system by an 8AWG (6AWG for Canada) wire. A lug for
bonding (2 for Canada) is provided on the outside/bottom of the Pro Logic enclosure.
Circuit Breaker Installation and Wiring
Circuit breakers are to be supplied by the installer. Refer to the circuit breaker chart on the following page for a list of
suitable circuit breakers that can be used. Follow the code and the circuit breaker manufacturers rating requirements
regarding the size and temperature rating for wiring. Note that some pool equipment may be required to be connected
to ground fault circuit breakers—check local and NEC (CEC) codes.
1021
Chemistry Config.
Wizard + to enter
Press to access Chemistry Config. Wizard
Move to previous/next menu item
Chemistry Configuration Wizard
Requires use of the optional AQL-CHEM Sensing Kit. Following the steps of the Chemistry Config.
Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if chlorination is used, can configure
the Pro Logic to generate the correct amount of chlorine to properly sanitize the pool. Refer to the AQL-
CHEM manual for more detailed information.
Pool/Spa Config.
+ to view/change
Pool/Spa Setup
Pool and Spa
Spa Spillover
Enabled
Filter Operation
Spa Spillover
Push to access Pool/Spa options
Rotates between Pool Only (default), Spa Only and
Pool and Spa
Toggle between Enabled and Disabled Spa Spillover
(default)
Toggle between Pool Only and Spa Spillover options
(default)
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to previous/next configuration menu
if “Pool and Spa” is
selected and
if “Spa Spillover” is enabled
Spa - CountDn
00:30
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item
if “Pool and Spa” is selected
if “Pool and Spa” is selected
V1=Aux1, V2=Aux2
Disabled
Toggle between Enabled and Disabled
(default)
if “Pool Only” or “Spa Only” is selected
Move to previous/next configuration menu
Filter Off Valve
Change: Enabled
Toggle between Enabled and Disabled (default)
if “Pool and Spa” is selected
Move to previous/next configuration menu
Pool/Spa Setup
If “Pool Only” or “Spa Only” are selected, then the pool/spa valves are not needed and pushing the POOL/
SPA button on the display/keypad will have no effect. If “Pool and Spa” is selected, then the pool/spa
suction and return valve actuators should be connected to the Pro Logic. Pressing the POOL/SPA button
on the display/keypad will allow the homeowner to alternate between pool and spa operation. For more
information on “Pool and Spa”, refer to the Plumbing section on pages 8.
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to “Pool and Spa”. This setting is the time, after you
manually switch the Pool/Spa valves to “Spa Only”, until the Pro Logic automatically returns the valves to
their previous positions. It is programmed in increments of 5 minutes, from “Manual On/Off” (0 minutes) to
“21:00” (21 hours). The filter is forced on during this time period.
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa”, the homeowner will be able to rotate through “Pool
Only” (both suction and return valves switched to pool), “Spa Only” (both suction and return valves
switched to spa) and “Spillover” (suction valve switched to pool and return valve switched to spa) by
successive presses of the “Pool/Spa button.
Filter Operation
If “Spa Spillover” is selected, the Pro Logic will automatically switch the pool/spa suction and return
valves to “spillover” at the start of the programmed pool filtering time period or when the super-chlorinate
function is turned on. The valves will remain in this position for the remainder of the super-chlorinate
period. This option is usually preferable because both the pool and spa water will be filtered and sanitized.
If “Pool Only” is selected, then the Pro Logic will switch the pool/spa valves to the “pool only” position
at the start of the programmed pool filtering time period or when the super-chlorinate function is turned on.
This may be desirable on some systems with in-floor cleaners because it allows the cleaner to operate all
the time the pool is being filtered and/or the super chlorinate is running.
High Voltage
Relays
“Local” Display
Control Power
Input
pH Dispense
Output
Subpanel
Valve Connectors
Heater Output
Temp Sensor Inputs
External Input
Remote Keypad
Flow Switch
Cell Connector
Wireless Base
Receiver Connector
AQL-CHEM Connector
Ground Bus Bar
Bonding Lug(s)
x
x
Siemens
Murray
Manufacturer
Single
Double
Quad
Twin
GFCB
Filler Plates
QP
QP QT
QT QPF
QF3
SUITABLE LISTED BREAKERS
Tightening
Torque
MP-T
MP-T
MH-T
MH-T MP-GT LX100FP
25lb-in
25lb-in
Page view 23