when the super-chlorinate function is turned on. The valves will remain in this position for
the remainder of the super-chlorinate period. This option is usually preferable because both
the pool and spa water will be filtered and sanitized.
If “Pool Only” is selected, then the Aqua Logic will switch the pool/spa valves to the “pool
only” position at the start of the programmed pool filtering time period or when the super-
chlorinate function is turned on. This may be desirable on some systems with in-floor
cleaners because it allows the cleaner to operate all the time the pool is being filtered and/or
the super chlorinate is running.
V1=Aux1, V2=Aux2
This menu appears only if the Pool/Spa Setup is “Pool Only” or “Spa Only”. When enabled,
Valve 1 (return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output.
When disabled (default), the return and suction pool/spa valves function normally.
Filter Off Valve Change
This menu appears only if Pool/Spa setup is set to “Pool and Spa”. When enabled (default),
the filter pump will shut off for 35 seconds whenever the Pool/Spa valves are turning. The
pump will NOT shut off when the heater has Cooldown enabled and is either on or in the
Heater Cooldown mode.
Filter Pump Config.
+ to view/change
Filter Name
Pool Filter
Filter Pump
1 Speed
Freeze Protect
Enabled
Flow Monitor
Disabled
Freeze Temp
38ºF
Push to access pump options
Rotates between all available names
Toggle between 1-speed (default) and 2-speed options
Toggle between Enabled (default) and Disabled Freeze Protection
Toggle between Enabled and Disabled Flow Monitor (default)
Adjust the desired freeze protection temperature (33ºF - 42ºF)
Move to next menu item
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Freeze Protect” is enabled
+
+
+
+
+
+
>
>
>
>
>
>
>
>
>
>
>
>
Filter Name
The Aqua Logic allows you to assign any one of a number of names (e.g. “Filter Pump, Pool
Filter, Spa Filter, etc.) to the filter relay. This will make the Aqua Logic more user friendly to the
homeowner when they want to control the filter equipment. A sheet of small name labels is
included with the Aqua Logic main unit and each remote display/keypad so that appropriate
pushbuttons can be labeled the same as the name that you have assigned.
Filter Pump
For 2-speed pumps: When a 2-speed pump is configured, one of the AUX relays must also
be configured to control the low speed motor winding on the pump (see page 14 for wiring
and page 31 for AUX configuration). See the Operation manual for specific information
regarding the control logic for 2-speed pump operation.
Flow Monitor
This feature will help protect the filter pump from damage due to no flow. When used with a
Goldline flow switch, the Aqua Logic monitors the state of water flow when the filter pump is
on. If no flow is detected for more than 15 minutes, the Aqua Logic will shut down the pool
pump and the “Check System” LED will indicate an error. The error will be cleared the next
time the pump is turned on.
24
and page 31 for AUX configuration). See the Operation manual for specific information
regarding the control logic for 2-speed pump operation.
Freeze Protection
Freeze protection is used to protect the spa and plumbed equipment against freeze damage.
If freeze protection is enabled and the AIR temperature sensor falls below the freeze threshold
(selectable in Filter Pump Configuration Menu - page 25), the Aqua Logic will turn on the spa
filter pump to circulate the water.
NOTE: The configuration parameters for all Aux outputs are same as shown below for Aux1. PS-4: Aux1 and Aux2.
PS-8: Aux1 through Aux6. PS-16: Aux1 through Aux14. Also note that for the PS-16, Valves7, 8, 9 and 10 are turned
On/Off with the control function selected for Aux7, 8, 9, and 10, respectively.
Aux1 Config.
+ to view/change
Aux1 Function
Manual On/Off
Aux1 Group
Filter: Unaffected
Aux1 Group
Timer: None(Manual)
Aux1 Name
Cleaner
Aux1 Relay
Standard
Push to access Aux options
Options available depend on the function that is selected
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Rotates between all available names
Toggle between Standard (default) and Dimmer
Move to previous/next configuration menu
Move to previous/next menu item or next configuration menu
Move to next configuration menu item
Move to next menu item
Move to next menu item or previous/next configuration menu
Aux1 Interlock
Disable
Aux1 Freeze
Disable
Toggle between Enabled and Disabled (default) Aux1 Interlock
Toggle between Enabled and Disabled Aux1 Freeze(default)
Move to next menu item
Move to previous/next configuration menu
+
+
+
+
+
+
+
+
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
for all functions except solar, dimmer relay,
low speed (filter pump), and group
for all functions except dimmer relay,
low speed, and group
for group function only
for group function only
for manual on/off, countdown
timer and timeclock functions
Rotates between
Manual On/Off (default), Countdown Timer, Low Speed-
Filter, Timeclock, Solar, Low speed-Spa Filter, Group & Super Chlorinate
Move to next menu item
!
WARNING: Do not use the Aqua Logic to control an automatic pool cover. Swim-
mers may become entrapped underneath the cover.
NOTE: If “Pool and Spa-Dual” is selected, Aux1 is dedicated to use as the spa filter. Its Name is set to Spa Filter, the
Function is set to Timeclock and Interlock is set to Disabled. These can’t be changed.
Aux1 Name
The Aqua Logic allows you to assign any one of a number of names (e.g. “Cleaner Pump,
Waterfall, Gazebo Light, etc.) to each of the aux outputs control function. This will make the
Aqua Logic much more user friendly to the homeowner when they want to turn various aux
equipment on or off or program the timeclocks. A sheet of small name labels is included with
the Aqua Logic main unit and each remote display/keypad so that the “Aux” pushbutton can
be labeled the same as the name that you have assigned. At this time it is also a good idea to
make sure that the relay in the control box is also labeled (hand written) with the same name
as a help to technicians who may service this system at a later date.
Aux1 Function
Manual On/Off (default)—the aux relay will alternate between turning on and off when the
aux button is pressed. There is no automatic control logic.
Countdown Timer – the aux relay will turn on when the AUX button is pressed and then will
turn off automatically after a programmed time (see Timers Menu in the Operations Manual).
The AUX button can also be used to turn the output off.