Two Speed Filter Pump: If the pump is currently off, simply press the “FILTER” button to turn on high
speed operation of the filter pump. The “Filter” LED will illuminate continuously. Pressing the “FILTER”
button again will switch to low speed operation and the “FILTER” LED will flash. If you attempt to switch
to low speed shortly after turning on high speed the filter pump will automatically remain in high speed for
3 minutes before switching to low speed to allow the pump to prime and establish normal water flow.
Freeze Protection: This function protects the pool, plumbing, and equipment against freeze damage. If
Freeze Protection is enabled and the AIR temperature sensor falls below the preset freeze protection
temperature (see Filter Pump Configuration), the Aqua Logic will turn on the filter pump to circulate the
water.
Spa Filter Pump (when using Dual Equipment)
Single Speed Filter Pump: If the pump is currently off, press the “AUX1” button to turn on the pump.
Pressing the “AUX1” button again will turn off the pump. However, if there is a heater in the system, and
it is operating, and the “Heater Cooldown” feature is enabled (Configuration Menu) then: when you press
the “AUX1” button to turn off the filter, only the heater will turn off, the Filter LED will flash and the display
will indicate “Heater Cooldown”. At this point the filter pump will automatically turn off after 5 minutes of
heater cooldown operation. If you want to override the heater cooldown, simply press the “AUX1”
button again to turn off the filter pump.
Two Speed Filter Pump: If the pump is currently off, simply press the “AUX1” button to turn on high
speed operation of the filter pump. The “AUX1” LED will illuminate continuously. Pressing the “AUX1”
button again will switch to low speed operation and the “AUX1” LED will flash. If you attempt to switch
to low speed shortly after turning on high speed the filter pump will automatically remain in high speed for
3 minutes before switching to low speed to allow the pump to prime and establish normal water flow.
Freeze Protection: This function protects the pool, plumbing, and equipment against freeze damage. If
Freeze Protection is enabled and the AIR temperature sensor falls below the preset freeze protection
temperature, the Aqua Logic will turn on the spa filter pump to circulate the water.
Lights and Aux Outputs
Standard Relay: Manual operation of all relays (LIGHTS, AUX1 and AUX2 for a PS-4 model, LIGHTS,
AUX1 - AUX6 for a PS-8 model, or LIGHTS, AUX1 - AUX14 for a PS-16 model) is identical. Assum-
ing that the relay is currently off, simply press the appropriate button to turn on the relay. If the relay does
not turn on, it probably is due to the “interlock” feature (which was set up in the Configuration Menu) being
activated that requires the filter pump to be running and the valves to be in the pool-only position. This
protects pumps and other equipment from possible damage. If the controlled output is on, pressing the
appropriate button again will turn off the relay. Manual turn off is disabled if the “Freeze Protection”
feature is enabled and the air temperature is less than the selected freeze temperature threshold.
Dimmer Relay: If Lights or an Aux output is configured as a dimmer, pressing the corresponding button
will generate a temporary display which shows the dimmer output level (Off - On 100%). Pushing the “+”
or “-” button changes the level in increments of 20%. When the desired output level is displayed, press the
corresponding button again to turn off the display and return to normal operation. When the Lights or Aux
output comes on again (either manually or automatically), the dimmer output level will be the same as the
last time that it was set.
Pool/Spa Valves
Pool-only or Spa-only systems: The POOL/SPA/SPILLOVER button has no function.
Standard Pool and Spa systems without spa spillover: In pool-only mode (“POOL” LED illuminated),
press the “POOL/SPA/SPILLOVER” button to switch to spa-only operation (“SPA” LED illuminated).
Pressing the “POOL/SPA/SPILLOVER” button again will switch back to pool-only. Note that the filter
pump will turn off while the pool/spa valves are turning.
39
Chlorinator Cell sensor -- if the chlorinator function enabled (Configuration Menu/Chlorinator) and
the cell sensor is either an open or short circuit.
PS-16 Communication Error -- if an AQL-PS-16 and the Expansion Unit is not responding.
Low Volts -- if the chlorinator cell voltage is too low.
No Cell Power -- if no chlorinator cell power is detected on the printed circuit board.
Chk Flow Switch -- if the flow switch input is invalid.
Cell Power Error -- if a chlorinator cell power error is detected on the printed circuit board.
No Flow-Filter Pump -- if the filter pump is on and the flow switch indicates no flow for 15 minutes or
more.
Cell Missing -- if the chlorinator is enabled but no cell is detected.
For helpful troubleshooting information on any of these issues, go to the Diagnostic Menu and then scroll
through the various items until you see the cause for the “CHECK SYSTEM” LED being illuminated.
Diagnostic Menu
To enter the Diagnostic Menu, press the “Menu” button repeatedly until the display shows “Diagnostic
Menu”. At this point, you can use either the “<” or “>” buttons to scroll through the various menu items
which are described below:
Set Day and Time
Wednesday 10:37P
Move to previous/next menu item
+23.45 +6.75A
84°F 3200PPM
Press to switch chlorinator operation to opposite polarity (15 second delay)
+
>
>
+/- 23.45V is the voltage applied to the chlorinator cell
+/-6.75A is the current (amps) through the cell
84ºF is the water temperature at the cell
3200PPM is the “instant” salt level at this time
For the chlorinator to be operating, several other things must be happening: the filter pump
must be running, the flow switch must be detecting flow, the chlorinator setting must be set
greater than 0%, the water temperature at the cell must be between 50ºF and 140ºF, and the
salt level must be within the operating range. If any of these conditions are not met, the
chlorinator diagnostic display will tell you the reason. It’s possible to have more than one
reason, in which case after you rectify what was displayed the first time, a second display will
appear.
If the current (amps) display is 0.00A, then the chlorinator is operating normally but is in the
off part of its normal operating cycle. Simply press either the “+” or “-“ key to start a new
cycle.
The Aqua Logic periodically reverses the polarity of the voltage applied to the cell in order
to automatically clean off any calcium deposits. It is important that you check the chlorinator
operation in both polarities. To do this, press either the “+” or “-“ buttons and the chlorinator
will turn off, wait for 15 seconds and then turn on in the opposite polarity.