12
!
Important: All of the displays shown below use the default generic names for each function
or output. The Aqua Logic allows more descriptive names to be assigned to each piece of equip-
ment (refer to the section regarding the Configuration Menu for more information).
For one speed pumps, this is the first filter timeclock and will determine the normal hours of
filtration for the pool. For pool/spa combination systems with spillover enabled and filter
operation set to “spillover”, the valves will automatically switch to spillover mode at the start
of the filtration period. For pool/spa combination systems with spillover enabled and filter
operation set to “pool only”, the valves will switch to the pool-only position. Refer to page
11 for general notes regarding timeclock programming.
For two speed pumps, this setting will be the period of time when the pump runs at high
speed (the word “Filter T1” in the display will be replaced with “Filter Hi”). There is a
separate timeclock for the low speed operation (see below). If the high speed and low speed
periods overlap, then the pump will operate in low speed during the overlap period.
There are several reasons the filter pump may be running at times other than the timeclock
period set above. These include super-chlorination, spa operation, manual operation, heater
cooldown, freeze protection, heater-extend and solar-extend.
For one speed pumps, this is the second filter timeclock
For two speed pumps, this timeclock will set the normal time period for filter pump low speed
operation (the word “Filter T2” in the display will be replaced with “Filter Lo”). If the filter
pump was off prior to the start of this time period, the filter pump will first turn on at high
speed for 3 minutes to prime and establish water flow. Afterwards, it will drop down to low
speed for the remainder of the programmed low speed time period. While this time clock will
override the high speed timeclock (see above), there are several reasons why the pump will
automatically switch to high speed operation during this programmed time period. These
include manual operation, spa operation, or heating operation.
This menu is only available if the system has been setup for “spa only” or “pool and spa”.
During the programmed spa time, the Aqua Logic will move the pool/spa valves into the
“spa-only” position and turn on the filter pump. The heater will automatically heat the spa
up to the programmed spa temperature. This programmed spa operation will take precedence
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Filter T1-all
8:30A to 4:00P
Adjust time s
Filter T1-wkend
8:30A to 4:00P
Filter T1-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
+
>
>
+
+
>
>
>
>
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Filter T2-all
8:30A to 4:00P
Adjust time s
Filter T2-wkend
8:30A to 4:00P
Filter T2-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
+
>
>
+
+
>
>
>
>
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Spa-all
6:00P to 9:00P
Adjust time s
Spa-
6:00P to 9:00P
wkend
Spa-wkday
6:00P to 9:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
+
>
>
+
+
>
>
>
>
31
Note: Separate chlorinator output levels for the pool and spa must be set. If the valves
are in the pool-only or spa spillover positions, then the chlorinator will operate per the
pool setting. If the valves are in the spa-only position then the chlorinator will operate
according to the spa setting. The actual amount of chlorine introduced into the pool/spa
is determined by: this output setting, the amount of time the filter pump is running, the
water temperature, and the amount of salt in the water. Also see Start/Stop
Supechlorination below.
Start/Stop Superchlorination
1. Press the “MENU” button repeatedly until “Settings Menu” is displayed
2. Press the “>” button repeatedly until “Super Chlorinate” is displayed.
3. The display will show whether superchlorination is “on” or “off”.
4. Press “+” or “-” to toggle between “on” and “off”
Note: Once started, superchlorination will run for the programmed number of hours
(Timers Menu/Super Chlorinate Hours) or until you manually turn it off.
Superchlorination may be temporarily interrupted for a programmed spa operation.
Program a Timeclock
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until the “xxx—all days” or “xxx—weekends” is displayed.
3. Use the “+” and “-“ buttons to set the desired start time, then press “>” to switch to the off
time. Use the “+” and “-“ buttons to adjust the off time. If you are setting the “weekend”
timeclock, press “>” to go to the “weekday” settings.
Note: During the programmed time, there may be other automatic or manual opera-
tions that prevent the relay/valve from operating—see a more detailed discussion under
Automatic System Operation/Timers Menu/Aux Timeclock or in Troubleshooting/Diag-
nostic Information.
Program a Countdown Timer
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until the “xxx—Timer” is displayed.
3. Use the “+” and “-“ buttons to set the desired timer period.
Note: A setting of 0:00 will display as “Manual On/Off.” The countdown automatic
turn off function is disabled by manual operation is still permitted. There may be other
automatic or manual operations that prevent the relay/valve from operating—see a
more detailed discussion under Automatic System Operation/Timers Menu/Aux Timeclock
or in Troubleshooting/Diagnostic Information.