Super Chlorinate
The Aqua Logic can be programmed to Super Chlorinate the pool or spa while running a group command.
When the Group starts, the Super Chlorinate cycle will begin. Super Chlorinate will continue until the
preset time expires (see Timers Menu/Super Chlorinate Hours) or until the Group turns off. Changing the
Super Chlorinate state using the Settings Menu, the Aqua Pod Super Chlorinate button, or a Super Chlo-
rinate assigned Aux/Lights/Valve button will temporarily cancel the Group’s control of Super Chlorinate
until the next time the Group is activated.
PS-8 and PS-16 Virtual Models
Aqua Logic Virtual models are similar to standard PS models, but offer additional auxiliary outputs with
limited functionality. The AQL-PS-8-V is similar to the AQL-PS-4 with 4 additional Aux outputs. The
AQL-PS-16-V is similar to the AQL-PS-8 with 8 additional outputs. The additional aux outputs on virtual
models can only be assigned to the Super Chlorinate function (if the Chlorinator is enabled) or to a Group
function. Refer to the following programming information when assigning functions to the virtual auxiliary
outputs.
Configuration Menus
Each item needs to be programmed and may contain additional sub-menu items. Refer to the following
pages for information on programming.
Cell Type
T- CE LL- 1 5
Toggle between T-CELL-5 and T-CELL-15
Move to next menu item
+
>
>
Chlorinator
Enabled
Display
Salt
Chlor. Config.
+ to view/change
Toggle between Enabled (default) and Disabled
Chlorinator
Toggle between Display Salt (default) and Minerals
Move to next menu item
Move to previous/next configuration menu
Move to next configuration menu
>
>
>
>
>
>
+
+
+
Push to access Chlorinator option
Chlorinator
If the chlorinator is enabled (requires the use of the AQL-CL chlorination kit), then the cell
and flow switch must also be installed and the Aqua Logic will automatically chlorinate both
the pool and spa according to the desired output setting (see Settings Menu in the Operation
manual). If disabled (default), then neither the cell nor flow switch need to be installed and
all displays relating to the chlorinator will be suppressed.
When the chlorinator is enabled, the Aqua Logic will automatically detect and control any
Aqua Rite(s) that is installed in the system (see page 21).
Display
Allows for the display of salt (default) or mineral values.
Cell Type Selection
The Cell Type Menu appears after “Display Salt/Minerals” in the Chlorinator Configuration
Menu. The options are T-CELL-5 or T-CELL-15 (default). Make the proper selection based
on the electrolytic cell that is used in your system. For pools up to 20,000 gallons, the T-
CELL-5 is typically used. The T-CELL-15 is for pools up to 40,000 gallons.
26
AQL-PS-8-V models only: Aux3 - Aux7 only
AQL-PS-16-V models only: Aux7 - Aux14 only
Aux7 Config.
+ to view/change
Aux7 Function
Group
Aux7 Group
Filter: Unaffected
Aux7 Group
Timer: None(Manual)
Push to access Virtual Aux options
Rotates between Super Chlorinate, Group and Manual On/Off
Options available depend on the function that is selected
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Move to previous/next configuration menu
Move to next menu item
Move to previous/next menu item or next configuration menu
Move to next configuration menu item
+
+
+
+
>
>
>
>
>
>
>
>
Aux7 Name
Cleaner
Rotates between all available names
Move to next menu item
+
>
>
For more information on the Group function, refer to page 22 in the Installation Manual. If neither Super
Chlorinate or a Group can be assigned to a Virtual Aux button, the following will be displayed:
No Virtual
Functions Available
NOTE: The configuration for Valve3 and Valve4 are identical. However, if Heater2 was enabled, then the Valve4
configuration will not appear (a single relay is used to implement either the Heater2 function or the Valve4 function-
-it can not do both). For PS-16, see aux logic on page 31 for control of Valves7, 8, 9 and 10.
Valve3 Freeze
Disabled
Toggle between Enabled and Disabled (default) Valve3 Freeze
Move to previous/next configuration menu
for all functions except group
+
>
Valve3 Config.
+ to view/change
Valve3 Function
Solar
Valve3 Name
Waterfall
Push to access Valve3 options
Rotates between Manual On/Off (default), Countdown Timer,
Timeclock, Solar, In-floor Cleaner, Group, and Super Chlorinate
Move to previous/next configuration menu
Move to next menu item
Valve3 Interlock
Disabled
Toggle between Enabled and Disabled (default) Valve3 Interlock
Move to next menu item
for all functions except solar and group
Rotates between all available names
Move to next menu item
+
>
>
+
+
+
>
>
>
>
>
>
>
Valve3 Group
Filter: Unaffected
Valve3 Group
Timer: None(Manual)
Options available depend on the function that is selected
Rotates between Manual On/Off (default),Countdown Timer and Timeclock
Move to previous/next menu item or next configuration menu
Move to next menu item
+
+
>
>
>
>
for group function only
for group function only
Valve3 Name
The Aqua Logic allows you to assign any one of a number of names (e.g. “Cleaner Valve,
Waterfall valve, Solar Valve, etc.) to each of the valve output control function. This will make
the Aqua Logic much more user friendly to the homeowner when they want to turn various
valves on or off or program the timeclocks. A sheet of small name labels is included with the
Aqua Logic main unit and each remote display/keypad so that the “Valve3” (and “Valve4”)
pushbutton can be labeled the same as the name that you have assigned.
Valve3 Function
Manual On/Off (default) – the valve3 relay will alternate between turning on and off when
the VALVE3 button is pressed. There is no automatic control logic. The VALVE3 button can
also be used to turn the valve output on or off.