Pool/Spa Config.
+ to view/change
Pool/Spa Setup
Pool and Spa-Std
Spa Spillover
Enabled
Heaters
Htr1=Spa,Htr2=Pool
Filter Operation
Spa Spillover
Push to access Pool/Spa options
Rotates between Pool and Spa-Std , Pool and Spa-Dual,
Pool Only, and Spa Only options
(default)
Toggle between Enabled and Disabled Spa Spillover(default)
Toggle between Htr1=Spa, Htr2=Pool (default) and Shared Heaters
Toggle between Pool Only and Spa Spillover options(default)
Move to previous/next configuration menu
Move to next menu item
Move to next menu item or previous/next configuration menu
Move to next menu item
Move to previous/next configuration menu
if “Pool and Spa-Std or Dual” is
selected and if “Spa Spillover” is enabled
+
+
>
>
>
>
+
+
+
>
>
>
>
>
Spa - CountDn
00:30
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
Move to next menu item
if “Pool and Spa-Std” is selected
if “Pool and Spa-Dual” is selected
if “Pool and Spa-Std or Dual” is selected
+
>
>
>
V1=Aux1, V2=Aux2
Disabled
Toggle between Enabled and Disabled
(default)
if “Pool Only” or “Spa Only” is selected
+
+
Move to previous/next configuration menu
>
>
>
>
Filter Off Valve
Change: Enabled
Toggle between Enabled and Disabled (default)
if “Pool and Spa-Std” is selected
Move to previous/next configuration menu
Pool/Spa Setup
If “Pool Only” or “Spa Only” are selected, then the pool/spa valves are not needed and
pushing the POOL/SPA button on the display/keypad will have no effect. If “Pool and Spa-
Std” is selected, then the pool/spa suction and return valve actuators should be connected
to the Aqua Logic. Pressing the POOL/SPA button on the display/keypad will allow the
homeowner to alternate between pool and spa operation. If “Pool and Spa-Dual” is selected,
then only the Pool/Spa return valve actuator should be connected to the Aqua Logic.
For more information on “Pool and Spa-Std” and “Pool and Spa-Dual”, refer to Section 3,
Plumbing, on pages 9-12.
Heaters
This menu will only appear if Pool/Spa setup is set to “Pool and Spa-Dual”. This allows the
heater(s) to either be shared between the pool and spa (“Shared” selected) or for Heater1 to
be dedicated to the spa and Heater2 to be dedicated to the pool (“Htr1=Spa, Htr2=Pool”
selected).
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to “Pool and Spa-Std”. This setting is the
time, after you manually switch the Pool/Spa valves to “Spa Only”, until the Aqua Logic
automatically returns the valves to their previous positions. It is programmed in increments
of 5 minutes, from “Manual On/Off” (0 minutes) to “21:00” (21 hours). The filter is forced on
during this time period.
Spa Spillover
When spa spillover is “Enabled” and “Pool and Spa-Std”, the homeowner will be able to
rotate through “Pool Only” (both suction and return valves switched to pool), “Spa Only”
(both suction and return valves switched to spa) and “Spillover” (suction valve switched to
pool and return valve switched to spa) by successive presses of the “Pool/Spa” button. For
“Pool and Spa-Dual”, only “Pool Only” and “Spillover” are available.
Filter Operation
If “Spa Spillover” is selected, the Aqua Logic will automatically switch the pool/spa suction
and return valves to “spillover” at the start of the programmed pool filtering time period or
25
Low Speed of a 2-speed Filter Pump – the Aqua Logic will operate the aux relay whenever
the low speed operation of the filter pump is required. It is very important that the “2-speed”
filter pump option be selected under the “Filter Config.” Menu for proper operation.
Timeclock – the aux relay will turn-on and turn-off at the times set for the aux timeclock in the
Timers Menu (see Operations Manual). The AUX button can also be used to turn the
output on and off.
Solar – the aux relay operates a solar booster pump which will turn on when the filter pump
is running and solar heat is available and the water is less than the desired temperature
setting. It is important to note that “Solar” must be enabled in the “Solar Config.” menu for
proper operation to occur.
Low Speed of a 2-Speed Spa Filter Pump – the Aqua Logic will turn on the aux relay
whenever the low speed operation of the Dual Equipment Spa filter pump is required. “Pool
and Spa-Dual” (located in Pool/Spa Setup menu) and “2-Speed” (located in Spa Filter Config.
menu) must be selected for proper operation.
Group – the aux relay operates when the Group function is initiated and shuts off when the
Group function is terminated. See Aux1 Group section for operation information for the
Group function.
Super Chlorinate – The Super Chlorinate function can be assigned to any Aux, Lights or
Valve button. This allows the user to simply hit a button to start a Super Chlorinate cycle,
rather than using the Settings Menu. Note that only one button can me assigned to this
function.
Aux1 Relay
This feature allows the user to select either “Standard” (default) or “Dimmer” type relay for
the Aux1 output. The optional AQL-DIM dimmer kit must be installed if “Dimmer” is desired.
When “Dimmer” is selected, and the Aux1 output is manually turned on, the “+” and “-”
buttons adjust the level from 20% to 100% (default). The level is saved for the next time the
aux1 output is turned from off to on.
Aux1 Interlock
If “Enabled”, this feature will override the function (Manual On/Off, Countdown Timer,
Timeclock), selected above and turn the aux1 off when: filter pump is off, first 3 minutes of
filter pump operation (allows the pump to prime and get water flowing), when the pool/spa
suction return valves are in any position other than “pool only”, or for the first 3 minutes
after solar turns on (allows air in the solar panels to be purged). Interlock is not available for
solar, low speed filter pump, dimmer, or group functions.
Aux1 Group
The Aux1 Group function allows the user to perform multiple tasks with a single push of the
“Aux1” button. When setting up a Group function, refer to page 22 for specific programming
information. There are two Group menus; the first menu determines how the group command
will be initiated (Manual On/Off, Countdown Timer, or Timeclock) and the second menu
selects the desired functions and their respective control parameters.
When activating Group functions, be aware that the most recent Group function that is
initiated will override any previous Group function.
Aux1 Freeze Protection
This function protects the pool, plumbing, and equipment against freeze damage. If Freeze
Protection is enabled and the AIR temperature sensor falls below the selected freeze protection
temperature, the Aqua Logic will turn on the aux relay to circulate the water. IMPORTANT:
this only enables operation of the AUX output during freeze--see the “Filter Pump Config.”
menu to enable freeze protection for the main circulation system. Freeze Protection is not
available for low speed filter pump, dimmer, or group functions.