over all other automatic functions, only manual operation of the filter button or pool/spa
valve button will override this function.
If your pool has a separate jet pump or blower controlled by Aux1 and/or Aux2 , you will have
to program those separately (see below).
This menu will appear only if the Lights are configured for timeclock. The lights will turn on
and off at the designated times. The only override on this function is manual on/off control
by the “Lights” button.
This menu will appear only if the Lights are configured for countdown timer. This setting is
the time after you manually turn on the lights until the Aqua Logic automatically turns off the
lights. You can also manually turn off the lights at an earlier time by pressing the LIGHTS
button.
This menu is only available if the system has been setup for Dual Equipment. For one speed
pumps, this is the first spa filter timeclock and will determine the normal hours of filtration for
the spa. For pool/spa combination systems with spillover enabled, the valves will automatically
switch to pool only at the start of the filtration period.
For two speed pumps, this setting will be the period of time when the spa pump runs at high
speed (the word “Spa Filter T1” in the display will be replaced with “Spa Filter Hi”). There is
a separate timeclock for the low speed operation (see below). If the high speed and low
speed periods overlap, then the pump will operate in low speed during the overlap period.
There are several reasons the spa filter pump may be running at times other than the timeclock
period set above. These include spa operation, manual operation, heater cooldown and
freeze protection.
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Lights-all
8:00P to 11:00P
Adjust time s
Lights-wkend
8:00P to 11:00P
Lights-wkday
8:00P to 11:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
or
Lights-CountDn
0:20
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:015...)
Move to previous/next menu item
+
>
>
+
+
+
>
>
>
>
>
>
Set Day and Time
Wednesday 10:37P
Adjust time setting
Move between start and stop times & to previous/next menu item
Spa Filter T1-all
8:30A to 4:00P
Adjust time s
Spa Filter T1-wkend
8:30A to 4:00P
Spa Filter T1-wkday
8:30A to 4:00P
Adjust time setting
Adjust time setting
Move between start and stop times & to previous/next menu item
Move between start and stop times & to previous/next menu item
or
+
>
>
+
+
>
>
>
>
30
Quick “How To” Guide
Operate the Spa—Manually
1. Press the “Pool/Spa” button to go to “spa-only” operation (“SPA” LED illuminated). In some
cases, this may take more than one press of the button.
2. If the filter pump is not already on, press the “FILTER” button to turn it on.
3. If the spa is below the desired temperature, the heater will turn on automatically when the filter
pump is on and the valves are in the spa-only position. If you have not already set the desired
temperature for the spa, see “Set Heater Temperature” below
4. If the spa has a separate jet pump and or blower, determine if the jet pump/blower is con-
trolled by Aux1 or Aux2 (it should be marked on the label inside the door). Then press the
appropriate button to turn on the jets/blower.
Operate the Spa—Automatically
1. Press the “MENU” button repeatedly until “Timers Menu” is displayed
2. Press the “>” button repeatedly until the “Spa—all days” or “Spa—weekends” is displayed.
3. Use the “+” and “-“ buttons to set the desired start time, then press “>” to switch to the off
time. Use the “+” and “-“ buttons to adjust the off time. If you are setting the “weekend”
timeclock, press “>” to go to the “weekday” settings.
Note: During the programmed spa time, the valves will automatically switch to the
“spa-only” position, the filter pump will turn on, and, if the spa is not up to the desired
temperature, the heater will start. This operation is the highest priority and will take
precedence over other automatically programmed operations. At the end of the spa
period, the Aqua Logic will return to its normally programmed operation state.
Set the Heater Temperature (or turn heater permanently off)
1. Press the “MENU” button repeatedly until “Settings Menu” is displayed
2. Press the “>” button repeatedly until the “Spa Heater” or “Pool Heater” is displayed.
3. Press the “+” or “-“ buttons repeatedly to adjust the temperature. If you adjust the tempera-
ture below 65ºF or above 104°F the display will indicate “off” and the heater will not operate
regardless of temperature.
Note: Separate temperatures for the pool and spa must be set. If the valves are in the
pool-only or spa spillover positions, then the heater will use the pool setting. If the
valves are in the spa-only position then the heater will operate according to the spa
setting.
Set the Chlorinator Output
1. Press the “MENU” button repeatedly until “Settings Menu” is displayed.
2. Press the “>” button repeatedly until the “Spa Chlorinator” or “Pool Chlorinator” is displayed.
3. Press the “+” or “-“ buttons repeatedly to adjust the setting. If you adjust the setting to 0% the
chlorinator will be off all the time.